How do I account for fuel used by the station's own vehicles and generator?
For station managers, accountants, owners · By the Petro team · Last reviewed
The short answer
Fuel the station uses itself is neither a sale nor a loss, so it must be recorded separately: litres, vehicle or generator, date and who drew it, at the time it is pumped. Take those litres off what the pumper owes for the shift, issue them from stock at cost, and charge the cost to an expense account. Then compare each vehicle's and the generator's use with the work they did, so own use cannot hide a loss.
Why does own use need its own record?
When a station's lorry, delivery van or generator is filled from the station's own pumps, the meter moves just as it would for a sale. If nothing is recorded, the pumper is asked to pay for fuel nobody paid them for, and looks short. If it is recorded loosely, as a note on the shift sheet, it is easy to over-record, and own use becomes a convenient place to hide fuel that was sold for cash or lost.
A proper record also gives you the true cost of running the station's vehicles and the generator, which belongs in your expenses rather than vanishing from your sales.
How should each fill be recorded?
- Fill only vehicles the owner has listed as the station's own, and the generator.
- Record at the time of the fill: date, pump, litres, the vehicle number or the generator, the driver or person who drew it, and the vehicle's odometer reading or the generator's running hours.
- Have the driver or person sign the record, and the pumper too.
- Take the litres off what the pumper owes for the shift, the same way a credit sale is taken off.
- Issue the litres from the tank's stock at cost, and charge the cost to an expense account, such as vehicle running costs or generator fuel.
How do I check that own use is reasonable?
- For each vehicle, divide the kilometres driven between fills by the litres put in, and watch the figure over time. A sudden drop in kilometres per litre needs explaining.
- For the generator, compare the litres with the running hours, and with the power cuts you know about.
- Compare the month's own use with last month and the same month last year.
- Check that fills were made only to listed vehicles, and that no vehicle was filled twice in a short time without a reason.
What about the generator's day tank and fuel bought in cans?
If the generator is filled from a can or a day tank, record the fill when the fuel leaves the station's pump or tank, not when it goes into the generator. Keep the day tank's level noted with the running hours. If fuel for the generator is bought from outside, record it as a purchase or an expense with its receipt, not as stock issued.
What about lubricants and oil used on the station's vehicles?
The same rule applies. Engine oil, grease or coolant taken from the shop's stock for the station's own vehicles is not a sale. Record the item, quantity and vehicle, issue it from stock at cost and charge it to the same running cost account, so the shop's stock and its sales figures stay right.
Frequently asked questions
- Should own-use fuel be charged at the pump price or at cost?
- At cost, for the books: the station has not sold the fuel, it has used it. It is still useful to know what it would have sold for, to see the value of what the station uses, but that figure is not income.
- Can the owner's private car be filled as own use?
- It is better to treat fuel for private use as the owner's drawings, or as a sale to the owner, rather than as a station expense. Ask your accountant how it should be recorded for your business.
- What if a driver fills up and forgets to record it?
- The pumper will show a shortage and the tank will show the litres as sold. Record the fill as soon as it is found, with the driver's signature, and correct the shift. Repeated forgotten fills are worth treating as a control problem.
- Does own use affect the dip and book stock check?
- Yes. Own use leaves the tank just like a sale, so the book stock must count it as fuel out. If it is left out of the records, the tank appears to be short by exactly those litres, and a real loss can be hidden behind it.
How Petro handles this
In Petro fuel for the station's own vehicles is entered on the shift's pump line as internal fuel usage, with the vehicle and the quantity, and is not billed to the pumper. When the shift is submitted, Petro issues those litres from the tank at cost and charges them to the Internal Fuel Usage Account, showing what they would have sold for, and only vehicles marked as internal appear. Lubricants and other store items used on the station's own vehicles are recorded as Internal Oil Usage and issued from stock at cost to the same account.
See fuel operations in PetroThis guide is general information for Sri Lankan fuel stations, written by the Petro team. Figures in examples are made up. For a decision about your own tax or legal position, check with your accountant or the authority named in the sources.